Anilam Mini Wizard A163 Manual Top (2025)

How to set the "zero" point for a part, or pre-load a coordinate. 5. Maintenance and Part Replacement

After this, you must re-enter your scale resolution and linear compensation. anilam mini wizard a163 manual top

On the X-axis parameter string, setting the leftmost digit to forces the unit to boot into Inch mode automatically by default. Physical Scale Installation and Realignment How to set the "zero" point for a

Used for entering coordinate dimensions and tool offsets. On the X-axis parameter string, setting the leftmost

If you want an axis to display a specific number instead of zero: Press the Axis Select key ( X or Y ). Type the desired numerical value using the keypad.

If your axis counts in the opposite direction after installation, look at the rear panel or inside the main housing. Anilam units frequently feature small toggle switches or internal wire jumpers labeled REV or DIR for each axis channel to reverse counting polarity. 6. Sourcing Replacement Parts and Upgrades